Moisture and Ionic Residue Can Exploit Weak Connector Plating

Mated charging contacts developed severe corrosion and electrical contact failures.

SEMEDSIn-situ contact inspectionMicrosectioningPlating measurementStock-part comparison
Preview image for Case 1069

What the evidence preview establishes

Condensed moisture combined with chloride, bromide, potassium, and other ionic residues to form a corrosive electrolyte. Porous, variable, separated, or locally missing plating increased access to the copper base.

Why this case matters

Connector corrosion is often a system interaction. Evaluate environment, cleanliness, and plating integrity together rather than treating gold thickness alone as adequate protection.