Case 2504 ยท Public preview

Coupled Devices Can Preserve Evidence of a Common Overstress Event

A controller IC and associated protection diode both developed abnormal leakage and severe internal damage.

Electrical testingOptical microscopyChemical decapsulationSEMEDSControl comparison
Preview image for Case 2504

What the evidence preview establishes

Both devices failed through gross electrical overstress. Fused copper in the controller and melted gold in the protection diode demonstrated extreme localized heating, although the sequence between an initiating ESD event and secondary overcurrent could not be resolved.

Why this case matters

When multiple protection-path devices fail together, map their circuit relationship before assigning ESD as the sole cause. Melted metals establish energy severity, not necessarily event sequence.

Full evidence reserved for MEMBER and STOREThe complete case includes the evidence sequence, four interpreted figures, alternative explanations, limitations, and practical application guidance.