Case 772 ยท Public preview
A Weak Inner-Layer Interface Can Open After Soldering Heat
Two signal nets were open between component solder joints and their first vias.
Electrical isolationMicrosectioningSEMBare-board comparisonQC-coupon comparison

What the evidence preview establishes
Inner-layer copper separated from electroless copper in plated-through component holes. As-fabricated comparisons already contained partial weakness, while soldering heat and drill breakout aggravated the failed connections.
Why this case matters
For an open near a plated-through joint, electrically bracket the fault, section the component hole, compare unassembled coupons, and separate pre-existing interface weakness from assembly damage.
Full evidence reserved for MEMBER and STOREThe complete case includes the evidence sequence, four interpreted figures, alternative explanations, limitations, and practical application guidance.