Case 2281 ยท Public preview

Interfacial Solder Fracture Does Not Necessarily Mean Black Pad

Components separated from an ENIG-finished board, prompting concern about black-pad syndrome.

SEMEDSMicrosectioningFractographyPhosphorus measurementIntermetallic comparison
Preview image for Case 2281

What the evidence preview establishes

The expected black-pad indicators were absent. Brittle interfacial fractures were instead associated with severe board delamination and limited board-side intermetallic development, supporting mechanical loading potentially aggravated by marginal reflow.

Why this case matters

Diagnose black pad from its metallurgical indicators, not from joint separation alone. Board delamination and asymmetric intermetallic growth can redirect the investigation toward mechanical and reflow history.

Full evidence reserved for MEMBER and STOREThe complete case includes the evidence sequence, four interpreted figures, alternative explanations, limitations, and practical application guidance.