Winding-Conductor Selection Can Eliminate Transformer Thermal Margin
Transformer assemblies exhibited severe overheating and charred insulation.
Electrical testingHi-pot testingTeardownMicrosectioningSEMDimensional comparison

What the evidence preview establishes
Electrical and construction comparisons linked the overheated condition to winding conductors that were substantially larger than those in a comparison design. The lower winding resistance was consistent with increased current and loss of thermal margin; dielectric breakdown between windings was not observed.
Why this case matters
A winding change that lowers DC resistance can alter system current and power dissipation even when the transformer appears well made. Electrical requirements, conductor geometry and application-level thermal margin must be reviewed together.
Full evidence reserved for MEMBER and STOREThe complete case includes the evidence sequence, four interpreted figures, alternative explanations, limitations, and practical application guidance.