Case 1465 ยท Public preview

Electrical Degradation Can Exist Without Visible Die Damage

Several voltage regulators showed degraded output behavior and repeatable forward-voltage shifts relative to a comparison device.

Electrical testingOptical microscopyChemical decapsulationSEMEDSControl comparison
Preview image for Case 1465

What the evidence preview establishes

Physical examination did not reveal the cause of the electrical degradation. Bond wires, pads, and die surfaces appeared normal, with no visible corrosion, EOS, or ESD site. Subtle junction contamination, an invisible parametric ESD defect, or lead damage remained possible.

Why this case matters

When electrical shifts are repeatable but the die looks normal, treat physical inspection as a narrowing step. Add temperature-dependent parametric testing, comparison-lot data, emission microscopy, deprocessing, and lead-resistance checks.

Full evidence reserved for MEMBER and STOREThe complete case includes the evidence sequence, four interpreted figures, alternative explanations, limitations, and practical application guidance.